Specifications
Description
Torque
105 lb.ft
Construction
Cast Iron/Steel
Weight
70 lb
Thermal Capacity
19 HPS/MIN
Inertia(Wk²)
0.233 lb.ft²
Enclosure
NEMA 2
Dimension (N)
2.75 in
Dimension (X)
2.00 in
Dimension (AC)
2.98 in
Dimension (C)
7.50 in
Reaction Time (Release and set)
20-25 ms
AK (Register)
10.5 in
AJ (Bolt Circle)
9.00 in
Maximum RPM
2400 rpm
Design Type
2 Post
Design Features
2 Post Design for standard applications
HEAVY DUTY 4 Post Design for high cycle/ jogging
No disassembly required for mounting
Direct acting design with no linkages to break
One moving part for longer life
Torque adjustable for specific applications
Splined hub
Coil insulation: Class B Standard, Class H Optional
Spring set, electrically released
Manual release, automatic reset
CSA Approved File #LR13814
Lead wires for conduit connections (internal connection available)
Enclosure Type
Drip-proof Enclosure:NEMA 2, CSA 2, IP41
Stamped steel cover with cast iron bracketor cast aluminum cover with cast iron bracket
Waterproof/Dusttight Enclosure: NEMA 4, CSA 4, IP56
Also available without hub seal for non-TEFC applications4 post model only 4-80000-32
Cast iron cover and bracket
Standard AC Voltages (Single and Three Phases)
(Y) - 110/220V, 50Hz|(U) - 230/460V, 60 Hz or 190/380V, 50 Hz|(R) - 115/230V, 60 Hz|(T) - 220/440V, 60 Hz|(P) - 575V, 60 Hz|
Standard Hub Bore Sizes
(F) - 7/8 in - (Keyway - 3/16 in x 3/32 in)|(H) - 1-1/8 in - (Keyway - 1/4 in x 1/8 in)|
|(J) - 1-1/4 in - (Keyway - 1/4 in x 1/8 in)|(K) - 1-3/8 in - (Keyway - 5/16 in x 5/32 in)|(M) - 1-5/8 in - (Keyway - 3/8 in x 3/16 in)|(N) - 1-7/8 in - (Keyway - 1/2 in x 1/4 in)
Available Options
(A) - Adapter to Larger Frame Size(s)|(AB) - Reverse Adapter|(P) - Tropical Protection|(Q) - Class H Insulation|(F) - Foot Mounting Bracket|(H) - Heavy-Duty Rotating Friction Disc with Hardened Steel Hub|(N) - Harsh Environment Protection|(R) - Internal Space Heater|(S) - Stainless Steel Stationary Disc|(T) - Through Shaft|(XS) - Micro-Switch Warning|(J) - High Tensile Studs|(M) - Marine Duty|(VO) - Vertical Over, or above motor (Vertical Mounting)|(VU) - Vertical Under, or below motor (Vertical Mounting)|(E) - Ductile Iron Stationary Disc
NEMA Frame Sizes 284TC and 286TC
ACCRO-MET, Inc.
Headquarters: Monroe, NC 28110
Toll Free:
800-543-4755 |
Phone:
704-283-2111 |
Fax:
704-283-2112
NE Location: East Granby, CT 06026
Toll Free:
800-543-4756 |
Phone:
860-844-0333 |
Fax:
860-844-0180
Web site:
www.accromet.com/
6-83105-57 , 80 Series End Mount 2 Post Design Dings Brake
NEMA Frame Sizes 284TC and 286TC
Torque
105 lb.ft
Construction
Cast Iron/Steel
Weight
70 lb
Thermal Capacity
19 HPS/MIN
Inertia(Wk²)
0.233 lb.ft²
Enclosure
NEMA 2
Dimension (N)
2.75 in
Dimension (X)
2.00 in
Dimension (AC)
2.98 in
Dimension (C)
7.50 in
Reaction Time (Release and set)
20-25 ms
AK (Register)
10.5 in
AJ (Bolt Circle)
9.00 in
Maximum RPM
2400 rpm
Design Type
2 Post
Design Features
2 Post Design for standard applications
HEAVY DUTY 4 Post Design for high cycle/ jogging
No disassembly required for mounting
Direct acting design with no linkages to break
One moving part for longer life
Torque adjustable for specific applications
Splined hub
Coil insulation: Class B Standard, Class H Optional
Spring set, electrically released
Manual release, automatic reset
CSA Approved File #LR13814
Lead wires for conduit connections (internal connection available)
Enclosure Type
Drip-proof Enclosure:NEMA 2, CSA 2, IP41
Stamped steel cover with cast iron bracketor cast aluminum cover with cast iron bracket
Waterproof/Dusttight Enclosure: NEMA 4, CSA 4, IP56
Also available without hub seal for non-TEFC applications4 post model only 4-80000-32
Cast iron cover and bracket
Standard AC Voltages (Single and Three Phases)
(Y) - 110/220V, 50Hz|(U) - 230/460V, 60 Hz or 190/380V, 50 Hz|(R) - 115/230V, 60 Hz|(T) - 220/440V, 60 Hz|(P) - 575V, 60 Hz|
Standard Hub Bore Sizes
(F) - 7/8 in - (Keyway - 3/16 in x 3/32 in)|(H) - 1-1/8 in - (Keyway - 1/4 in x 1/8 in)|
|(J) - 1-1/4 in - (Keyway - 1/4 in x 1/8 in)|(K) - 1-3/8 in - (Keyway - 5/16 in x 5/32 in)|(M) - 1-5/8 in - (Keyway - 3/8 in x 3/16 in)|(N) - 1-7/8 in - (Keyway - 1/2 in x 1/4 in)
Available Options
(A) - Adapter to Larger Frame Size(s)|(AB) - Reverse Adapter|(P) - Tropical Protection|(Q) - Class H Insulation|(F) - Foot Mounting Bracket|(H) - Heavy-Duty Rotating Friction Disc with Hardened Steel Hub|(N) - Harsh Environment Protection|(R) - Internal Space Heater|(S) - Stainless Steel Stationary Disc|(T) - Through Shaft|(XS) - Micro-Switch Warning|(J) - High Tensile Studs|(M) - Marine Duty|(VO) - Vertical Over, or above motor (Vertical Mounting)|(VU) - Vertical Under, or below motor (Vertical Mounting)|(E) - Ductile Iron Stationary Disc
Envelope Icon
small picture of an envelope signifying email
0
Contact Us
×
Close
Quick View